Kavli Affiliate: Wei Gao
| Summary:
This paper presents pre-launch testing and calibration results for the SVOM/VT (Space-based Variable Objects Monitor, Visible Telescope) Flight Model (FM), validating its performance under simulated space conditions through thermal vacuum cycling, energy concentration analysis, stray light suppression, and CCD/electronics calibrations (gain, noise, quantum efficiency). The results confirm full compliance with design requirements: stray light suppression achieves point-source transmittance $<10^-7$ at $30^circ$ off-axis, thermal control maintains stable CCD temperatures ($-75^circ$C for the red channel, $-65^circ$C for the blue channel), and detection sensitivity meets the limiting magnitude of 22.50 (SNR $>$ 3 with 300 seconds exposure). Early in-orbit tests further validate performance, yielding limiting magnitudes of 22.70 (V-band, red) and 22.78 (blue), consistent with pre-launch specifications.
| Search Query:arXiv Query: search_query=au:”Gao Wei”&id_list=&start=0&max_results=10